Composition
Polyester non-woven fabric, polyester film, super absorbent resin, dhesive
Application
Be used for water-blocking in neutral screen wire between cable components.
Property | Unit | Type | Test Method | |
|---|---|---|---|---|
| YNWF-25 | YNWF-30 | |||
Thickness | mm | 0.25±0.03 | 0.30±0.03 | ISO9073-2 |
| Mass per unit area | g/m² | 110±10 | 140±10 | ISO9073-1 |
| Tensile strength | N/cm | ≥20 | ≥40 | ISO9073-3 |
| Elongation | % | ≥8 | ≥8 | ISO9073-3 |
| Swelling speed | mm/1’00 | ≥6 | ≥6 | YS Method |
| Swelling height | mm/3’00 | ≥12 | ≥12 | YS Method |
| Short-term stability | ℃ | 230 | 230 | YS Method |
| Long-term stability | ℃ | 90 | 90 | IEC216 |
| Moisture content | % | ≤9 | ≤9 | ISO287 |